To size a worm gear hose clamp, measure the outside diameter of the hose with the fitting already inside it, then pick the SAE size whose clamping range brackets that number with your hose sitting near the middle of the range. The SAE number on the packet is a code, not a diameter, but it has a pattern you can use: in the standard series the number is roughly the clamp’s maximum diameter, counted in sixteenths of an inch, minus eight.
Most size charts hand you a table and stop. This one teaches you to read the table, so you can sanity-check any chart, spot a mislabelled packet and choose confidently between two clamps whose ranges overlap. You will find the chart itself below, a decoding rule, four measuring methods, worked examples and a list of the errors that cause most returns.
Three numbers describe every worm gear clamp
A worm gear (worm drive) clamp carries three figures, and it helps to keep them apart.
| Number | Meaning | Where you see it |
|---|---|---|
| SAE size | A code that identifies the clamp’s range, such as #16 or #24 | Packet label, catalogue |
| Clamping range | The smallest and largest diameter the band can close around | Packet label, product page |
| Band width | The width of the steel strip, such as 5/16, 1/2, 9/16 or 5/8 in | Product page, specification table |
The SAE system comes from the standard that defines worm drive clamps for automotive use. SAE J1508 covers 32 types of clamp for coolant, fuel, oil, vacuum and emission systems, and the size numbers you see on packets follow that tradition. Our explainer on the SAE J1508 standard gives the background.
Two cautions come with that. First, the same SAE number on a mini clamp and a standard clamp does not mean the same range. Mini clamps use a narrower 5/16 inch band and their own ranges, which a hose-clamp retailer flags as the most common sizing confusion in its SAE size chart guide. Second, ranges vary slightly between makers, especially at the small end, so the table below shows typical values to learn from, not a replacement for the packet in your hand.
Worm gear hose clamp size chart (standard series)
This chart lists the common full-size clamps with a 1/2 inch band, in inches and millimetres. Values are typical and drawn from catalogue charts by several suppliers, so check them against the exact product before you buy.
| SAE size | Clamping range (in) | Clamping range (mm) | Max diameter in sixteenths | Max minus 8 |
|---|---|---|---|---|
| 6 | 3/8 to 7/8 | 10 to 22 | 14 | 6 |
| 8 | 7/16 to 1 | 11 to 25 | 16 | 8 |
| 10 | 9/16 to 1-1/16 | 14 to 27 | 17 | 9 (exception) |
| 12 | 11/16 to 1-1/4 | 17 to 32 | 20 | 12 |
| 16 | 13/16 to 1-1/2 | 21 to 38 | 24 | 16 |
| 20 | 13/16 to 1-3/4 | 21 to 44 | 28 | 20 |
| 24 | 1-1/16 to 2 | 27 to 51 | 32 | 24 |
| 28 | 1-5/16 to 2-1/4 | 33 to 57 | 36 | 28 |
| 36 | 1-13/16 to 2-3/4 | 46 to 70 | 44 | 36 |
| 40 | 2-1/16 to 3 | 52 to 76 | 48 | 40 |
| 52 | 2-13/16 to 3-3/4 | 71 to 95 | 60 | 52 |
| 56 | 3 to 4 | 76 to 101 | 64 | 56 |
Sources used for the typical values include the AFT Fasteners size chart, the Garage Tooled sizes chart and the McMaster-Carr clamp assortments, which list SAE numbers 10, 12, 16, 24, 36 and 40 with their ranges. Minimum diameters differ by a sixteenth or two between suppliers, which is normal.
Larger sizes
Above about 4 inches, catalogues agree well on the maximum diameter and less on the minimum, because makers differ in how much band they allow.
| SAE size | Maximum diameter (in) | Maximum diameter (mm) |
|---|---|---|
| 80 | 5-1/2 | 140 |
| 88 | 6 | 152 |
| 96 | 6-1/2 | 165 |
| 104 | 7 | 178 |
| 128 | 8-1/2 | 216 |
| 152 | 10 | 254 |
| 188 | 12-1/4 | 311 |
Maximums come from the catalogue pages cited above and a dealer clamp catalogue. For a hose near any of these sizes, confirm the minimum on the specific part.
The decoding rule: SAE number equals max diameter in sixteenths minus 8
Look at the last column of the chart. Take the maximum diameter, express it in sixteenths of an inch, and subtract eight. For SAE 24 the maximum is 2 inches, which is 32 sixteenths, and 32 minus 8 gives 24. For SAE 56 the maximum is 4 inches, which is 64 sixteenths, and 64 minus 8 gives 56. It also works at the top of the scale: SAE 128 has a maximum of 8-1/2 inches, which is 136 sixteenths, and 136 minus 8 gives 128. It fits every standard size in the two tables except #10, which is off by one.
This is an observation, not part of the standard. We checked it against the sizes listed above and found it holds for the full-size series from #6 upward, and fails for the mini sizes. It is still handy in three ways:
- Reading an unfamiliar packet. A clamp marked #44 should reach about 3-1/4 inches at the top end (3.25 inches is 52 sixteenths, minus 8 is 44). If the label says a maximum of 2 inches, something is mislabelled.
- Checking a chart. A table that lists SAE 36 with a maximum of 3 inches breaks the pattern and deserves a second look.
- Estimating a size you have no chart for. Convert your hose OD to sixteenths, add a margin so the hose lands mid-range, and subtract eight.
The rule tells you about the maximum only. The minimum depends on how much band the maker leaves in the housing, so always read the range for the lower end.
How to measure a hose for a worm gear clamp
Accurate sizing starts with one rule: measure the hose in its working condition. A bare hose, or a hose off its fitting, is a different size from a hose stretched over a barb. McMaster-Carr’s guidance states the method plainly: measure the outside diameter of your hose with the fitting installed, and pick a clamp that places the figure in the middle of the clamp’s range. See its clamp selection notes.
Method 1: calipers (best)
- Push the hose fully onto the fitting.
- Close the caliper jaws gently across the hose at the position where the clamp will sit, just behind the bead or barb.
- Read the diameter and repeat at 90 degrees. Hoses are rarely perfectly round, so use the average.
- Write the figure in inches and millimetres.
Method 2: flexible tape or string
For hoses that are awkward to caliper, wrap a flexible tape, a strip of paper or a length of string around the hose at the clamp position. Mark where the end meets the length, then measure from the start to the mark. This gives the circumference. Divide by 3.14 to get the diameter. A circumference of 150 mm gives an OD of about 47.8 mm, and a circumference of 6 inches gives an OD of about 1.91 inches.
Pull the tape snug but not tight. A tight pull on soft hose compresses it and understates the size.
Method 3: from an old clamp
If the old clamp is the right type, open it fully and measure its open length, then divide by 3.14. That gives the largest diameter it could close on. It is a useful check, but old clamps may be mis-sized, stretched or wrong for the joint, so treat it as a clue, not a spec.
Method 4: from the fitting and the hose wall
When the hose is not yet on the fitting, estimate: hose OD at the clamp equals fitting OD at the barb plus twice the hose wall thickness, plus any stretch. This is the least precise method. Use it to shortlist sizes, then measure the real joint.
Choose from the middle of the range
Overlapping sizes make the choice harder. A 1-1/4 inch hose OD fits SAE 12, 16, 20 and 24 on the chart. Which one?
The answer is the clamp whose range puts the hose near the middle. One supplier’s guide describes the extremes clearly: if the hose sits at the very top of the range, you will struggle to get the clamp over the barb, and if it sits at the very bottom, you can run out of thread before the connection seals. See that discussion in Zoro’s size chart guide.
To make this concrete, compute the hose’s position in range:
position = (hose OD minus clamp minimum) divided by (clamp maximum minus clamp minimum)
A position of 0 percent means the hose is at the smallest the clamp closes on, and 100 percent means the largest. As a working rule of thumb, which is general engineering guidance and not a maker’s figure, aim for roughly 35 to 65 percent. Below 25 percent you have a long tail of spare band, and above 80 percent you have little adjustment left.
Four worked examples
All hose figures are illustrative measurements of the hose with the fitting installed.
Example 1: a heater hose measuring 1.42 inches
Candidates are SAE 16 (13/16 to 1-1/2, so 0.8125 to 1.5), SAE 20 (0.8125 to 1.75) and SAE 24 (1.0625 to 2.0).
| Clamp | Position in range | Verdict |
|---|---|---|
| SAE 16 | (1.42 minus 0.8125) divided by 0.6875 = 88 percent | Too close to the top |
| SAE 20 | (1.42 minus 0.8125) divided by 0.9375 = 65 percent | Good |
| SAE 24 | (1.42 minus 1.0625) divided by 0.9375 = 38 percent | Good, longer tail |
Choose SAE 20 for a neat result, or SAE 24 if space beside the housing is generous.
Example 2: a coolant hose measuring 2.35 inches
SAE 32 (about 1-9/16 to 2-1/2) would sit near the top. SAE 36 (1.8125 to 2.75) puts the hose at (2.35 minus 1.8125) divided by 0.9375 = 57 percent. Choose SAE 36.
Example 3: a silicone elbow measuring 3.40 inches
SAE 52 (2.8125 to 3.75) places it at 63 percent, and SAE 56 (3 to 4) places it at 40 percent. Both work. Because the hose is silicone, the more important decision is whether the clamp has a liner. See why hose clamps cut into hoses before you choose.
Example 4: a large intake hose measuring 6.2 inches
SAE 96 reaches a maximum of 6.5 inches, so a 6.2 inch hose would sit high in its range, depending on that clamp’s minimum. SAE 104, with a 7 inch maximum, gives more adjustment. Check the minimum on the actual part, since makers differ at this size.
Mini clamps and the small-hose trap
Under about an inch of hose OD, the mini series takes over. These clamps use a 5/16 inch band and a smaller screw, with ranges that overlap the standard series without matching it. A mini clamp marked with the same SAE number as a standard clamp has a different range, and a different torque limit.
OneTouch lists mini clamps with their ranges in the title, for example the 4SC004M for 0.25 to 0.63 inch, the 4SS0004 all-stainless version for 0.22 to 0.63 inch, and the 4SC006M for 0.44 to 0.78 inch. We have a full table in the mini hose clamp size chart and an explanation of the narrow band in what is a mini hose clamp.
Band width: the other half of sizing
Two clamps of the same SAE size can have different band widths, and band width changes how the clamp loads the hose. Common widths are:
| Band width | Typical use |
|---|---|
| 5/16 in (about 8 mm) | Mini clamps, small hoses |
| 1/2 in (about 12.7 mm) | Standard worm gear clamps |
| 9/16 in | Wider standard and constant tension clamps |
| 5/8 in (about 15.9 mm) | Hi-torque, heavy-duty and large hose clamps |
| 9 mm and 12 mm | German-type (DIN) clamps |
Wider bands spread the load, resist cutting into soft hose and handle more torque. Our article on hose clamp band width goes deeper. If you work in metric DIN sizes rather than SAE, use the German type hose clamp size chart instead.
Reading OneTouch part numbers
OneTouch worm gear clamps in the perforated worm gear clamp category usually carry a number at the end of the part code that follows the SAE size. For example, the 4SC0016 is a 1/2 inch band clamp spanning 13/16 to 1-1/2 inches, which matches SAE 16 on the chart above. The all-stainless 4SS series follows the same numbering. The product page always shows the exact range in inches, so read it there and not from the code alone.
Going backwards: from a clamp you already have to its size
Sometimes you hold a clamp with no packet. This reverse lookup works for the standard 1/2 inch band series.
- Open the clamp fully and lay it flat, with the screw housing at one end.
- Measure the open length of the band from the housing to the tail end, in millimetres.
- Divide by 3.14. The result is the largest diameter the band can close around.
- Compare that to the maximum column in the tables above. A figure near 51 mm points to SAE 24, near 57 mm to SAE 28, and near 76 mm to SAE 40.
- Use the decoding rule to confirm: convert the maximum to sixteenths, subtract eight, and see whether the result is close to a standard number.
Treat the answer as a good guess. Bands stretch, and a clamp that was over-tightened in the past will read a little long.
A starter assortment: six sizes that cover most jobs
If you keep clamps on a workshop shelf, a handful of overlapping sizes beats a drawer full of random ones. Ranges overlap by design, so six sizes chosen well will cover hoses from about 1/2 inch up to 3 inches with the hose landing in the mid-range of at least one clamp.
| Size to stock | Covers hose OD roughly | Typical jobs |
|---|---|---|
| SAE 10 | 9/16 to 1-1/16 in | Small heater and vacuum hoses, fuel hose |
| SAE 16 | 13/16 to 1-1/2 in | Heater hoses, small coolant hoses |
| SAE 24 | 1-1/16 to 2 in | Radiator hoses, water pump hoses |
| SAE 28 | 1-5/16 to 2-1/4 in | Larger radiator and intake hoses |
| SAE 36 | 1-13/16 to 2-3/4 in | Intake and large coolant hoses |
| SAE 40 or 52 | 2-1/16 to 3 in, or 2-13/16 to 3-3/4 in | Air intake ducts, larger coolant hoses |
Add mini clamps for fuel and vacuum lines under about three quarters of an inch, and add lined versions of the sizes you use on silicone. Keep a few constant tension clamps for joints that cycle between hot and cold. This table is a starting point and every shop is different, so adjust it to the hoses you actually meet.
Temperature and swelling: measure the hose as it will live
A hose changes size with temperature, fluid and age. Rubber and silicone expand when hot and shrink when cold. A hose measured on a cold morning is slightly smaller than the same hose at running temperature, and a hose that has soaked in fuel or coolant for months may swell a little. For clamp sizing these effects are small compared with the width of a typical range, and that is another reason to choose a clamp that puts the hose mid-range, leaving room both ways.
Where the swing is large, a stock clamp is a poor match for the physics. The loosening article, why hose clamps loosen over time, explains why a constant tension clamp is worth considering on joints with big temperature swings.
Eight sizing errors that cause returns
| Error | Why it fails | Fix |
|---|---|---|
| Measuring hose inside diameter | The clamp wraps the outside | Measure OD with the fitting installed |
| Measuring the bare hose | Hose swells over the barb | Measure on the fitting |
| Choosing a clamp where the hose sits at the maximum | Hard to fit, little reserve | Move up a size |
| Choosing where the hose sits at the minimum | Screw may run out of thread | Move down a size |
| Treating the SAE number as inches | #16 is not 16 inches | Read the range, not the code |
| Mixing mini and standard charts | Different ranges and torque | Check band width |
| Ignoring the bead | Band rides on the bead | Measure behind the bead |
| Using one brand’s chart for another’s part | Ranges differ slightly | Read the range on the packet |
For a quick, general lookup by inch size, our pages for the 1 inch, 2 inch, 3 inch and 4 inch hose sizes show which clamps cover each diameter, and the general hose clamp size chart in mm and inches covers all clamp families together.
After sizing: three things before you tighten
Choosing the right range is half the job. Before you tighten, check three further points.
- Position. Place the clamp behind the bead or barb on supported hose, not over the end of the hose.
- Torque. Standard worm gear clamps carry a torque rating, and OneTouch lists 45 inch-pounds on its 1/2 inch band clamps. A rating is a ceiling, not a target. See how to install a worm gear hose clamp for the method.
- Material. A correctly sized clamp in the wrong material will still fail. Our guide to choosing a worm gear hose clamp covers band, liner and screw choices, and the explainer what is a worm gear hose clamp covers the basics.
If you are unsure of a size or have an existing clamp to replace, the OneTouch cross-reference tool can match a competitor part number, and the quote page is where to send your hose OD, band width and quantity. Unfamiliar terms are defined in the hose clamp glossary.
Frequently asked questions
How do I know what size worm gear clamp I need?
Measure the outside diameter of the hose with the fitting installed, then choose the clamp whose range brackets that number with the hose near the middle. Check the range printed on the packet or product page, not only the SAE number.
What does the SAE number on a hose clamp mean?
It is a size code that identifies the clamp’s range. In the standard full-size series, the number is roughly the maximum diameter in sixteenths of an inch minus eight, so SAE 24 reaches about 2 inches. The rule is an observation that fits the common sizes, not part of the standard.
Is a hose clamp measured by inside or outside diameter?
Outside diameter of the hose, measured with the fitting inside it. The clamp wraps the hose from outside, so the hose’s outer surface sets the size.
Should the hose be in the middle of the clamp’s range?
Yes, ideally. At the top of the range the clamp is hard to fit over the barb, and at the bottom the screw may run out of thread. Around 35 to 65 percent of the range is a sensible working target.
What size hose clamp fits a 1 inch hose?
It depends on the hose’s measured outside diameter with the fitting installed, which is larger than the nominal 1 inch. A 1 inch ID hose often measures about 1.25 to 1.5 inches over the barb, which points to SAE 16, 20 or 24. Always measure.
What is the difference between a mini and a standard hose clamp?
A mini clamp uses a narrower 5/16 inch band and a smaller screw for small hoses, while a standard clamp uses a 1/2 inch band. The same SAE number on each can mean a different range, so check band width and range.
Can I use a bigger clamp and tighten it more?
A clamp that is too large leaves a long, loose tail and an uneven squeeze, and tightening harder risks cutting the hose or stripping the band. Choose the size whose range puts the hose in the middle instead.